Selected References BASIC DESIGN
Flare gas recovery and washing with MDEA solution process
Details
Year
2016
Client
ENI
Refinery
Sannazzaro Refinery - ENI
Location
Sannazzaro - Italy
Plant
Unit 72/93
Unit Products
2300 Std Vol rate(m3/h) of flare gas
Scope
Define the Duty Spec. containing all process information necessary for the selection of compressor package technology, used to recover flare gas and transfer it to washing section where the MDEA solution decrease the H2S content up to value ≤ 100 ppm Vol.
Our Work
- Selection a new compressor package technology
- Carry out a thermodynamic simulation for new washing section of flare gas with MDEA solution, to decrease the H2S content
- Design of new equipments (heat exchangers, column, pipes, PSV, instrumentation)